Sign In | Join Free | My chinaqualitycrafts.com
China WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD logo
WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD
WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD
Site Member

8 Years

Home > Yokogawa Flowmeter >

YOKOGAWA AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH axf080G flowmeter Yokogawa flow meter

WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD

YOKOGAWA AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH axf080G flowmeter Yokogawa flow meter

  • 1
  • 2

Place of Origin : Japan

Brand Name : Yokogawa

Model Number : axf125g flwometer

Packaging Details : original Yokogawa package in carton

Delivery Time : 6-8 weeks

Payment Terms : Paypal, Aliexpress, Western Union, T/T

Supply Ability : 200 pcs / week

MOQ : 1

Contact Now

Quick Details

  • Place of Origin:Japan
  • Brand Name:Yokogawa
  • Model Number:AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH

Packaging & Delivery

Packaging Details: in carton or according to custom's service
Delivery Detail: 2 weeks

Specifications

YOKOGAWA AXF Magnetic Flowmeter Remote Converter
1.Outstanding reliability
2.Compact and Light-weight Converter

ADMAG AXF Magnetic Flowmeters

The AXF magnetic flowmeter is sophisticated product with outstanding reliability and ease of operation, developed on the basis of decades of fieldproven experience.
The AXF magnetic flowmeter is significantly easier to maintain thanks to the combination of replaceable electrodes and a diagnostic function that detects the adhesion level on the electrodes. The AXF also employs a dual frequency excitation method (available for sizes up to 400 mm / 16 in.) that eliminates fluid noise. A newly enhanced dual frequency excitation method is also available as an option for more difficult applications to ensure greater stability and quicker response.
Based on FOUNDATION™ fieldbus specifications, AXF Fieldbus models offer more flexible instrumentation through a higher level communication capability and propose the cost reduction by multi-drop wirings with less cables.
FOUNDATION™ fieldbus is a registered trademark of Fieldbus FOUNDATION.
Note: The “Dual Frequency Excitation Method” is a Yokogawa innovation.

Features:ADMAG AXF Magnetic Flowmeters

User-oriented Functionality

Fluid Adhesion Level Diagnosis

The amount of insulating material on the electrode is constantly monitored to determine when maintenance should be performed. An optional replaceable electrode is easy to remove and clean.
Flexible Electrical Connection Direction
The converter or the terminal box can be rotated in either direction to match the position of the electrical connections at the installation site.
Clear and Versatile Indications
The large, backlit full dot matrix LCD can display a variety of messages up to three lines in length. When an alarm condition occurs, a full description of the appropriate countermeasure is displayed.
Easy Setup
The most frequently used parameters are arranged in a group at the top of the display. Infrared switches enable the setting of parameters without opening the cover.
Operation Immediately after Installation
The AXF is shipped with the main parameters completely set and can go into operation as soon as installation and wiring are completed.
Expansion of Product Lineup

Improved Accuracy Specification

The standard accuracy is 0.35% of reading. Also available as an option is high accuracy calibration rated at 0.2% of reading.
Extra Small Size Flange Type
Flange types are now available in sizes as small as 2.5 mm.
Variety of Sanitary Connections
A wider variety of sanitary connections are now available, including Tri-Clamp, ISO, DIN and SMS.
Enhanced Performance

Enhanced Dual Frequency Excitation

The enhanced dual frequency excitation method is available as an option. This provides highly stable measurements involving high concentration slurries or low conductivity fluids.
Lower Minimum Conductivity.
The newly designed AXF converter permits the measurement of fluids with conductivity as low as 1μS/cm depending on the nominal pipe size and fluid condition.
High-Speed Pulse Output:
The maximum rate for high speed applications such as short-duration batch processes is now 10,000 pps (pulses per second).

Specifications: ADMAG AXF Magnetic Flowmeters

AXF Remote Flowtube AXF Integral Flowmeter AXFA14 Converter AXFA11 Converter
Nominal Pipe Size 2.5 to 2600 mm
(0.1 to 104 in.)
[depends on model type and process connection type]
2.5 to 400 mm
(0.1 to 16 in.)
[depends on model type and process connection type]
For Flowtube
size ; 2.5 to 400mm
(0.1 to 16 in.)
For Flowtube
size ; 2.5 to 2600mm
(0.1 to 104 in.)
Type of use General-purpose use,
Ex-proof type,
Sanitary type,
Submersible type
General-purpose use,
Ex-proof type,
Sanitary type
General-purpose use,
Ex-proof type
General-purpose use
Fluid Temp. -40~160 deg.C (-40 to 320 deg.F)
(-10 to 160 deg.C (14 to 320 deg.F) for Sanitary type)
- 40~130 deg.C (-40 to 266 deg.F)
(-10 to 130 deg.C (14 to 266 deg.F) for Sanitary type)
- -
Ambient Temp. -40 to 60 deg.C (-40 to 140 deg.F) [ depends on model type ]
Accuracy 0.35% of rate (Optional ; 0.2% of rate)
Fluid Conductivity 1 micro-S/cm or larger (depends on nominal pipe size and fluid condition)
Lining Fluorocarbon PFA/Ceramics/Polyurethance Rubber/
EPDM Rubber/ Natural Soft Rubber
[depends on model type]
- -
Process Connection Wafer, Flange, Sanitary connections
(Clamp[Tri-clamp, DIN, ISO], Union thread[DIN, ISO SMS], Butt-weld), etc.
- -
Maximum Cable Length - - 100m
(330 ft)
200m
(660 ft)
Indicator - Multi line backlit LCD (Full dot-matrix)
Diagnosis Adhesion diagnosis, Empty pipe, Coil open, etc.
Alarm message Alarm message with corrective measures is indicated (English, German, French, Italian, Spanish, Japanese)
Excitation method Dual frequency excitation: size 2.5 to 400mm,
Pulsed DC excitation: size 500 to 2600 mm,
Enhanced dual frequency excitation (optional): size 25 to 200 mm
Ex-proof type ATEX, FM, CSA, IECEx, TIIS -
Options Replaceable electrode, Rotatable terminal box(converter), Mirror finished lining surface(for PFA/Ceramics), Special gaskets, etc.

Ordering Examples:

AXF002C-D-1-A-E-1-N-AA1-1-2-1-B

AXF002C-E-1-A-E-1-N-AA1-1-2-1-B

AXF002C-F-1-A-E-1-N-AA1-1-2-1-B

AXF002C-D-2-A-E-1-N-AA1-1-2-1-B

AXF002C-E-2-A-E-1-N-AA1-1-2-1-B

AXF002C-F-2-A-E-1-N-AA1-1-2-1-B

AXF002C-D-1-C-E-1-N-AA1-1-2-1-B

AXF002C-E-1-C-E-1-N-AA1-1-2-1-B

AXF002C-F-1-C-E-1-N-AA1-1-2-1-B

AXF002C-D-2-C-E-1-N-AA1-1-2-1-B

AXF002C-E-2-C-E-1-N-AA1-1-2-1-B

AXF002C-F-2-C-E-1-N-AA1-1-2-1-B

AXF002C-D-1-A-H-1-N-AA1-1-2-1-B

AXF002C-E-1-A-H-1-N-AA1-1-2-1-B

AXF002C-F-1-A-H-1-N-AA1-1-2-1-B

AXF002C-D-1-A-L-1-N-AA1-1-2-1-B

AXF002C-E-1-A-L-1-N-AA1-1-2-1-B

AXF002C-F-1-A-L-1-N-AA1-1-2-1-B

AXF002C-D-1-A-P-1-N-AA1-1-2-1-B

AXF002C-E-1-A-P-1-N-AA1-1-2-1-B

AXF002C-F-1-A-P-1-N-AA1-1-2-1-B

AXF065G-D-2-A-L-1-N-AA2-1-0-1-B/CH

AXF065G-E-2-A-W-1-N-AA2-1-0-1-B/CH

AXF065G-D-1-A-L-1-N-AA2-1-0-1-B/CH

AXF065G-E-1-A-W-1-N-AA2-1-0-1-B/CH

AXF065G-D-1-A-L-1-N-AA1-1-0-1-B/CH

AXF065G-E-1-A-W-1-N-AA1-1-0-1-B/CH

AXF065G-D-2-U-L-1-N-AA2-1-0-1-B/CH

AXF065G-E-2-U-W-1-N-AA2-1-0-1-B/CH

AXF065G-D-1-U-L-1-N-AA2-1-0-1-B/CH

AXF065G-E-1-U-W-1-N-AA2-1-0-1-B/CH

AXF065G-D-1-U-L-1-N-AA1-1-0-1-B/CH

AXF065G-E-1-U-W-1-N-AA1-1-0-1-B/CH

AXF080G-D-2-A-L-1-N-AA2-1-0-1-B/CH

AXF080G-E-2-A-W-1-N-AA2-1-0-1-B/CH

AXF080G-D-1-A-L-1-N-AA2-1-0-1-B/CH

AXF080G-E-1-A-W-1-N-AA2-1-0-1-B/CH

AXF080G-D-1-A-L-1-N-AA1-1-0-1-B/CH

AXF080G-E-1-A-W-1-N-AA1-1-0-1-B/CH

AXF080G-D-2-U-L-1-N-AA2-1-0-1-B/CH

AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH

AXF080G-D-1-U-L-1-N-AA2-1-0-1-B/CH

AXF080G-E-1-U-W-1-N-AA2-1-0-1-B/CH

AXF080G-D-1-U-L-1-N-AA1-1-0-1-B/CH

AXF080G-E-1-U-W-1-N-AA1-1-0-1-B/CH

AXF100G-D-2-A-L-1-N-AA2-1-0-1-B/CH

AXF100G-E-2-A-W-1-N-AA2-1-0-1-B/CH

AXF100G-D-1-A-L-1-N-AA2-1-0-1-B/CH

AXF100G-E-1-A-W-1-N-AA2-1-0-1-B/CH

AXF100G-D-1-A-L-1-N-AA1-1-0-1-B/CH

AXF100G-E-1-A-W-1-N-AA1-1-0-1-B/CH

AXF100G-D-2-U-L-1-N-AA2-1-0-1-B/CH

AXF100G-E-2-U-W-1-N-AA2-1-0-1-B/CH

AXF100G-D-1-U-L-1-N-AA2-1-0-1-B/CH

AXF100G-E-1-U-W-1-N-AA2-1-0-1-B/CH

AXF100G-D-1-U-L-1-N-AA1-1-0-1-B/CH

AXF100G-E-1-U-W-1-N-AA1-1-0-1-B/CH

AXF065C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH

AXF065C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH

AXF065C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH

AXF065C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH

YOKOGAWA AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH axf080G flowmeter Yokogawa flow meter


Product Tags:

yokogawa Magnetic Flowmeter

      

AXF100

      

AXF100G

      
Quality YOKOGAWA AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH axf080G flowmeter Yokogawa flow meter for sale

YOKOGAWA AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH axf080G flowmeter Yokogawa flow meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)